The Kestrel 5400 is a highly accurate handheld, portable, WBGT (Wet Bulb Globe Temperature) measurement device and environmental data logger. It requires no distilled water, bulky globes, complicated setup or expensive equipment. Simply hold or place the Kestrel 5400 at the location required and immediate and average WBGT data will be stored and displayed. You can set thresholds and will be made instantly aware if they are exceeded by a loud buzzer, bright LED beacon and on-screen warnings enabling you to manage dangerous conditions quickly and with accurate information at hand.
Uniquely the Kestrel 5400 is also a complete weather station measuring wind speed, maximum wind gusts, temperature, humidity, pressure, wind chill, density altitude and more, making the Kestrel 5400 the ideal product when determining safe working conditions, setting rest breaks and maximising personnel performance.
-
WBGT (Wet Bulb Globe Temperature)
-
Does not require distilled water
-
Large easily read high resolution, high contrast display with backlight
-
Time & Date
-
Customize screens to display user-selected measurements
-
Graph & recall trends
-
Min, Max & Average values
-
Automatically store measurements, when powered on or off
-
Manually store measurements with the press of a button
-
Customizable data storage – 10,000 data points
-
Data charting
-
Optional LiNK connectivity powered by Bluetooth® low energy provides wireless communication to mobile devices and computers
-
Data upload to iOS & Android phones & tablets
-
Data upload to Windows or Mac computers with optional USB Data Cable
-
Data upload to Windows & Mac computers via wireless Bluetooth (LiNK Enabled Meters only with the optional Kestrel Dongle)
-
Standard user-replaceable AA Lithium Battery (Average Life 400 Hours)
-
Drop tested to MIL-STD-810G standards (10 drops from 4′)
-
Waterproof and dustproof (sealed to IP67 standards – 30′ submersion to 3′)
-
Certificate of Conformity
-
Neck Lanyard
-
Patented Impeller and Sensor Technology (user-replaceable)
-
Impeller cover allows use of other functions whilst protecting the impeller
-
Waterproof & Floats
-
Languages: English, French, Spanish, German & Italian
- 5 Year Warranty
Sensor | Accuracy (+/-) | Resolution | Specification Range | Notes |
Wind Speed | Air Flow | Larger of 3% of reading, least significant digit or 20 ft/min | 0.1 m/s 1 ft/min 0.1 km/h 0.1 mph 0.1 knots 1 B* 0.1 F/S* |
0.6 to 40.0 m/s 118 to 7,874 ft/min 2.2 to 144.0 km/h 1.3 to 89.5 mph 1.2 to 77.8 knots 0 to 12 B* 2-131.2* |
1 inch|25 mm diameter impeller with precision axle and low-friction Zytel® bearings. Startup speed stated as lower limit, readings may be taken down to 0.4 m/s | 79 ft/min| 1.5 km/h | .9 mph | .8 kt after impeller startup. Off-axis accuracy -1% @ 5° off-axis; -2% @ 10°; -3% @ 15°. Calibration drift < 1% after 100 hours use at 16 MPH | 7 m/s. Replacement impeller (NK PN-0801) field installs without tools (US Patent 5,783,753). Wind speed calibration and testing should be done with triangle on impeller located at the top front face of the Kestrel. Measuring wind speeds above 60 m/s / 134.2 mph can damage the impeller. *F/S only in Ballistics units. Beaufort not available in Ballistics units. |
Ambient Temperature | 0.9 °F 0.5 °C |
0.1 °F 0.1 °C |
-20.0 to 158.0 °F -29.0 to 70.0 °C |
Airflow of 2.2 mph|1 m/s or greater provides fastest response and reduction of insolation effect. For greatest accuracy, avoid direct sunlight on the temperature sensor and prolonged sunlight exposure to the unit in low airflow conditions. Calibration drift is negligible for the life of the product. For further details, see Display & Battery Operational Temperature Limits |
Relative Humidity | ±2%RH | 0.1 %RH | 10 to 90% 25°C non-condensing | To achieve stated accuracy, unit must be permitted to equilibrate to external temperature when exposed to large, rapid temperature changes and be kept out of direct sunlight. Calibration drift is typically less than ±0.25% per year. |
Pressure | ±1.5 mbar at 25°C, 700-1100 mbar/ ±0.044inHg at 77°F 20.67-32.48 inHg/ ±0.022 PSI 10.15-15.95 PS |
0.01 inHg 0.1 hPa|mbar 0.01 PSI |
25°C/77°F, 700-1100 mbar/20.67-32.48 inHg/10.15-15.95 PSI |
Monolithic silicon piezoresistive pressure sensor with second-order temperature correction. Between 1100–1200 mbar, unit will operate with reduced accuracy. Sensor may not operate above 1200 mbar and can be damaged above 6,000 mbar or below 10 mbar. Calibration drift is negligible for the life of the product. |
Compass | ±5° | 1° 1/16th Cardinal Scale |
0 to 360° | 2-axis solid-state magnetoresistive sensor mounted perpendicular to unit plane. Accuracy of sensor dependent upon unit’s vertical position. Self-calibration routine eliminates magnetic error from batteries or unit and must be run after every full power-down (battery removal or change). Readout indicates direction to which the back of the unit is pointed when held in a vertical orientation. Declination/variation adjustable for True North readout. |
Calculated Measurements
Measurement | Accuracy (+/-) | Resolution | Sensors Deployed |
Air Density | 0.0002 lb/ft3 0.0033 kg/m3 |
0.001 lbs/ft3 0.001 kg/m3 |
Temperature Relative Humidity Pressure |
Air Flow | 6.71% | 1 cfm 1 m3/hr 1 m3/m 0.1m3/s 1 L/s |
Air Flow User Input (Duct Shape & Size) |
Altitude | typical: 23.6 ft/7.2 m – 50 to 1100 mBar max: 48.2 ft/14.7 m – 300 to 750 mBar |
1 ft 1 m |
Pressure User Input (Reference Pressure) |
Barometric Pressure | 0.07 inHg 2.4 hPa|mbar 0.03 PSI |
0.01 inHg 0.1 hPa|mbar 0.01 PSI |
Pressure User Input (Reference Altitude) |
Crosswind & Headwind / Tailwind | 7.1% | 1 mph 1 ft/min 0.1 km/h 0.1 m/s 0.1 knots |
Wind Speed Compass |
Delta T | 3.2 °F 1.8 °C |
0.1 °F 0.1 °C |
Temperature Relative Humidity Pressure |
Density Altitude | 226 ft 69 m |
1 ft 1 m |
Temperature Relative Humidity Pressure |
Dew Point | 3.4 °F 1.9 °C 15-95% RH. Refer to Range for Temperature Sensor |
0.1 °F 0.1 °C |
Temperature Relative Humidity |
Evaporation Rate | 0.01 lb/ft2/hr 0.06 kg/m2/hr |
0.01 b/ft2/hr 0.01 kg/m2/hr |
Wind Speed Temperature Relative Humidity Pressure User Input (Concrete Temperature) |
Heat Index | 7.1°F 4.0°C |
0.1 °F 0.1 °C |
Temperature Relative Humidity |
Moisture Content | Humidity Ratio (“Grains”) | .3gpp .4g/kg |
0.1 gpp 0.01 g/kg |
Temperature Relative Humidity Pressure |
Relative Air Density | 0.3% | 0.1% | Temperature Relative Humidity Pressure |
Wet Bulb Temperature – Psychrometric | 3.2 °F 1.8 °C |
0.1 °F 0.1 °C |
Temperature Relative Humidity Pressure |
Wind Chill | 1.6 °F 0.9 °C |
0.1 °F 0.1 °C |
Wind Speed Temperature |
Additional Product Info
Display & Backlight | Multifunction, multi-digit monochrome dot-matrix display. Choice of white or red LED backlight. |
Response Time & Display Update | Display updates every 1 second. After exposure to large environmental changes, all sensors require an equilibration period to reach stated accuracy. Measurements employing RH may require longer periods particularly after prolonged exposure to very high or very low humidity. |
Data Storage & Graphical Display, Min/Max/Avg History | Logged history stored and displayed for every measured value. Manual and auto data storage. Min/Max/Avg history may be reset independently. Auto-store interval settable from 2 seconds to 12 hours, overwrite on or off. Logs even when display off except for 2 and 5 second intervals. Kestrel 5 series units hold over 10,000 data points. |
Data Upload & Bluetooth® Data Connect Option | Wireless range up to 100ft. Connection requires optional USB data transfer cable or Kestrel Link Dongle or Kestrel LiNK app. Employs Kestrel Link protocol for data transmission with Link supported devices. (Kestrel LiNK for iOS/Android, Kestrel Link for PC/MAC). |
Clock / Calendar | Real-time hours:minutes:seconds clock, calendar, automatic leap-year adjustment. |
Auto Shutdown | User-selectable – Off, 15-60 minutes with no key presses. |
Languages | English, French, German, Spanish. |
Certifications | CE certified, RoHS and WEEE compliant. Individually tested to NIST-traceable standards. |
Origin | Designed and manufactured in the USA from US and imported components. Complies with Regional Value Content and Tariff Code Transformation requirements for NAFTA Preference Criterion B. |
Battery Life | AA Lithium, included. Up to 400 hours of use, reduced by backlight or Bluetooth radio transmission use. |
Shock Resistance | MIL-STD-810g, Transit Shock, Method 516.5 Procedure IV; unit only; impact may damage replaceable impeller. |
Sealing | Waterproof (IP67 and NEMA-6) |
Display & Battery Operational Temperature Limits | 14° F to 131° F | -10 °C to 55 °C Measurements may be taken beyond the limits of the operational temperature range of the display and batteries by maintaining the unit within the operational range and then exposing it to the more extreme environment for the minimum time necessary to take reading |
Storage Temperature | -22.0 °F to 140.0 °F | -30.0 °C to 60.0 °C. |
Size & Weight | 5.0 x 1.9 x 1.1 in / 12.7 x 4.5 x 2.8 cm, 4.3 oz / 121 g. (Lithium battery included) |
Refund Policy
Returns & Exchanges Policy
RETURNING THE PURCHASE
- Refunds on Cash On Delivery (COD) orders will be credited to your MMT eWallet, which can be used for future purchases. Future purchases will be subject to the same COD/shipping fee procedures, if applicable.
- Credit Card returns will be credited back to your original credit card.
- Value Added Tax (VAT) on the product purchased will be refunded.
- If an item you ordered is unavailable, we will notify you by email as soon as possible. If payment has already been made, refunds will be credited back to the original payment card used for the transaction.
- MMT eWallet credits have an expiry period of 12 months.
ORGANISING RETURNS OR EXCHANGES FOR REGISTERED CUSTOMERS
- To organize a return or exchange, registered users must log in to their registered account. Navigate to ‘My Account’ and then to ‘Returns & Exchanges’ to submit your request. The request for a refund must be made within 14 days of receiving your order. You will receive a notification upon completing the request.
- You can track your return or exchange by clicking on ‘Track Your Order’.
ORGANISING RETURNS OR EXCHANGES FOR GUEST USERS
- Guest users must submit a request via email to info@mmt.com within 14 days of receiving their order. Alternatively, you can contact Customer Care at +966-548907080 from Saturday to Thursday , 8:00 am to 8:00 pm (GMT+4). During Ramadan, our working hours are from 8:00 am to 8:00 pm, Monday to Friday.
ADDITIONAL INFORMATION
- Returned items must be received within 14 days of receiving the full order. Returns received after this period will not be processed and will be returned at your expense.
- If you placed an order with multiple items, you can only request a return once all items from your order have been delivered.
- Return or exchange of items is only permissible once.
- Any additional items returned that were not included in the approved list will be sent back to you, and shipping costs will be charged.
- All items must be returned in one package and in their original packaging with all tags attached. This includes any belts or designer packaging included with the item. If items are not returned in their original state, or are used and without tags, they will be sent back to you, and you will incur shipping charges. You will not be allowed to choose your shipping method; returns will be processed through our designated shipping companies only.
- All items are quality checked before dispatch. If you receive a damaged or faulty item, please log in to your registered account, go to ‘My Account’, and follow the steps within 48 hours of receiving your order. Guest users can submit a request via the ‘Track Your Order’ page.
- You will receive an email confirming that your return or exchange item(s) has been received, and the refund will be processed accordingly.
MMT RIGHTS
- MMT reserves the right to refuse refunds or exchanges on items deemed unfit for resale.
- Returns made outside the 14-day timeframe will not be accepted and will be returned to you at your expense.