Description
- Description
- Features
- Specifications
- Downloads
Description
The Fluke 6500-2 PAT tester is a low weight, small size, one-touch solution with redesigned auto-test capabilities to help you increase the number of portable appliance tests completed each day. The 6500-2 is designed to enable you to work faster without compromising test results.
Features
- Dedicated key for each test for ‘one-touch’ testing
- Complies with the new standards BS EN 50678 and BS EN 50699
- Pre-set pass/fail levels to save time
- Large backlit display for easy reading
- Single mains socket for appliance connection
- Separate IEC socket for easy mains/extension lead testing
- Detachable test leads for quick field replacement
- Integral carrying handle
- USB port for data transfer
- Integral QWERTY keyboard for rapid data entry
- Additional USB memory capability for back-up data storage and transfer to PC
- Large backlit graphics display
- Pre-set, auto-test sequences for user convenience
- Integral site, location and description codes for faster data processing
- Memory review facility for more on-site control
- USB port for data transfer
Specifications
Specifications | ||
Test specifications | The accuracy specification for the display range is defined as ±(%reading + digit counts) at 23 °C ±5 °C, ≤75% RH. | |
Between 0 °C and 18 °C and between 28 °C and 40 °C, accuracy specifications may degrade by 0.1 x (accuracy specification) per °C. | ||
The measurement range meets the service operating errors specified in EN61557-1: 1997, EN61557-2: 1997, EN61557-4: 1997, EN61557-6: 1997, DIN VDE0404-2. | ||
Power-on test | The test indicates reversed L-N, missing PE, and measures the mains voltage and frequency. | |
Display range | 90 V to 264 V | |
Accuracy at 50 Hz | ±(2% + 3 counts) | |
Resolution | 0.1 V | |
Input impedance | > 1 MΩ // 2.2 nF | |
Maximum input mains voltage | 264 V | |
Earth bond test (Rpe) | Display Range | 0 to 19.99 Ω |
Accuracy (after bond test zeroing) | ±(5% + 4 counts) | |
Resolution | 0.01 Ω | |
Test current | 200 mA AC -0% +40% into 1.99 Ω 10 A AC ±20% into 25 mΩ at 230 V |
|
Open circuit voltage | > 4 V AC, < 24 V AC | |
Bond test zeroing | can subtract up to 1.99 Ω | |
Insulation test (Riso) | Display range | 0 to 299 MΩ |
Accuracy | ±(5% + 2 counts) from 0.1 to 300 MΩ | |
Resolution | 0.01 MΩ (0 to 19.99 MΩ) 0.1 MΩ (20 to 199.9 MΩ) 1 MΩ (200 to 299 MΩ) |
|
Test voltage | 500 V DC -0% + 25% at 500 kΩ load or 250 V dc -0% +25% at 250 kΩ load | |
Test current | > 1 mA at 500 kΩ load, < 15 mA at 0 Ω | |
Auto discharge time | < 0.5 s for 1 μF | |
Max. capacitive load | Operational up to 1 μF | |
Touch current test | Display range | 0 to 1.99 mA AC |
Accuracy | ±(4% + 2 counts) | |
Resolution | 0.01 mA | |
Internal resistance (via probe) | 2 kΩ | |
Measuring method | Probe* | |
Substitute leakage current test | Display range | 0 to 19.99 mA AC |
Accuracy | ±(2.5% + 3 counts) | |
Resolution | 0.01 mA | |
Test Voltage | 100 V AC ±20% | |
Load/leakage test: load current | Display range | 0 A to 13 A |
Accuracy | ±(4% + 2 counts) | |
Resolution | 0.1 A* | |
Load/leakage test: load power | Display range 230 V Mains | 0.0 VA to 3.2 kVA |
Accuracy | ±(5% + 3 counts) | |
Resolution | 1 VA (0 to 999 VA), 0.1 kVA (>1.0 kVA)* | |
Load/leakage test: leakage current | Display range | 0 to 19.99 mA |
Accuracy | ±(4% + 4 counts) | |
Resolution | 0.01 mA* | |
PELV test | Accuracy at 50 Hz | ±(2% + 3 counts) |
Overload protection | 300 V rms | |
Warning threshold | 25 V rms | |
RCD test: trip current | Operational error | ±10% |
Nominal | 30 mA | |
Accuracy | ±5% | |
RCD test: trip time | Standard requirement | 61557 Part 6; tolerance of rated test current 0% to +10% |
Operational error | ±10% | |
RCD type | AC general-purpose 30 mA | |
Display range | 310 ms | |
Resolution | 0.1 ms | |
Accuracy | 3 ms | |
Trip time limit at 100% (30 mA) | 300 ms | |
Trip time limit at 500% (150 mA) | 40 ms | |
*The appliance under test is energized at mains potential. |
Environmental specifications | |
Operating temperature | 0 to 40 °C |
Relative humidity | Non condensing <10 °C |
95% from 10 to 30 °C | |
75% from 30 to 40 °C |
Safety specifications | |
Safety rating | Complies with EN61010-1 3rd edition |
CAT II, 300 V, pol 2 |
Mechanical and general specifications | ||
Size (L x W x H) | 200 x 275 x 114 mm | |
Weight | 3.13 kg | |
Power supply | 230 V +10% -15%, 50 Hz ±2 Hz or (6500-2 only: 110V +10% -15%,50 Hz ±2 Hz) | |
Power consumption (tester) | 13 W typical (idle) 60 W max. during 25A Bond test |
|
Storage | Temperature | -10 to 60 °C |
Corrosion | 70 °C @ 95% RH for 5 days max. | |
Operating altitude | 0 up to 2000 m | |
Sealing | IP-40 (enclosure), IP-20 (connectors) | |
EMC | Complies with EN61326-1, portable | |
EMI Immunity | 3 V/m |
Downloads
Refund Policy
Returns & Exchanges Policy
RETURNING THE PURCHASE
- Refunds on Cash On Delivery (COD) orders will be credited to your MMT eWallet, which can be used for future purchases. Future purchases will be subject to the same COD/shipping fee procedures, if applicable.
- Credit Card returns will be credited back to your original credit card.
- Value Added Tax (VAT) on the product purchased will be refunded.
- If an item you ordered is unavailable, we will notify you by email as soon as possible. If payment has already been made, refunds will be credited back to the original payment card used for the transaction.
- MMT eWallet credits have an expiry period of 12 months.
ORGANISING RETURNS OR EXCHANGES FOR REGISTERED CUSTOMERS
- To organize a return or exchange, registered users must log in to their registered account. Navigate to ‘My Account’ and then to ‘Returns & Exchanges’ to submit your request. The request for a refund must be made within 14 days of receiving your order. You will receive a notification upon completing the request.
- You can track your return or exchange by clicking on ‘Track Your Order’.
ORGANISING RETURNS OR EXCHANGES FOR GUEST USERS
- Guest users must submit a request via email to info@mmt.com within 14 days of receiving their order. Alternatively, you can contact Customer Care at +966-548907080 from Saturday to Thursday , 8:00 am to 8:00 pm (GMT+4). During Ramadan, our working hours are from 8:00 am to 8:00 pm, Monday to Friday.
ADDITIONAL INFORMATION
- Returned items must be received within 14 days of receiving the full order. Returns received after this period will not be processed and will be returned at your expense.
- If you placed an order with multiple items, you can only request a return once all items from your order have been delivered.
- Return or exchange of items is only permissible once.
- Any additional items returned that were not included in the approved list will be sent back to you, and shipping costs will be charged.
- All items must be returned in one package and in their original packaging with all tags attached. This includes any belts or designer packaging included with the item. If items are not returned in their original state, or are used and without tags, they will be sent back to you, and you will incur shipping charges. You will not be allowed to choose your shipping method; returns will be processed through our designated shipping companies only.
- All items are quality checked before dispatch. If you receive a damaged or faulty item, please log in to your registered account, go to ‘My Account’, and follow the steps within 48 hours of receiving your order. Guest users can submit a request via the ‘Track Your Order’ page.
- You will receive an email confirming that your return or exchange item(s) has been received, and the refund will be processed accordingly.
MMT RIGHTS
- MMT reserves the right to refuse refunds or exchanges on items deemed unfit for resale.
- Returns made outside the 14-day timeframe will not be accepted and will be returned to you at your expense.