The Fluke 1577 Insulation Multimeter combine a digital insulation tester with a full-featured, true RMS digital multimeter in a single, compact, handheld unit, which provides maximum versatility for both troubleshooting and preventative maintenance.
| Specifications | ||
| Voltage DC | Maximum voltage | 1000 V |
| Accuracy | ±(0.2%+2) | |
| Maximum resolution | 0.001 V | |
| Voltage AC | Maximum voltage | 1000 V |
| Accuracy | ±(2%+3) | |
| Maximum resolution | 0.1 mV | |
| Current DC | Maximum amps | 400 mA |
| Amps accuracy | ±(1.0%+2) | |
| Maximum resolution | 0.01 mA | |
| Current AC | Maximum amps | 400 mA |
| Amps accuracy | ±(2.0%+2)* | |
| Maximum resolution | 0.01 mA | |
| Resistance | Maximum resistance | 50 MΩ |
| Accuracy | ±(1.2%+2) | |
| maximum resolution | 0.1Ω | |
| Insulation Test | ||
| Minimum test current @ 1kΩ/V | 1 mA | |
| Test voltages | 500, 1000 V | |
| Maximum resistance per test voltage | 50 V | |
| 100 V | ||
| 250 V | ||
| 500 V | ||
| 1000 V | 600 MΩ | |
| Maximum resolution per test voltage | 50 V | 0.01 MΩ |
| 100 V | 0.01 MΩ | |
| 250 V | 0.1 MΩ | |
| 500 V | 0.1 MΩ | |
| 1000 V | 0.1 MΩ | |
| Accuracy per test voltage | 50 V | ±(3% + 5) |
| 100 V | ±(3% + 5) | |
| 250 V | ±(1.5% + 5) | |
| 500 V | ±(2.0% + 5) | |
| 1000 V | ±(2.0% + 5) | |
| Environmental Specifications | ||
| Operating temperature | –20°C to +55°C | |
| Storage temperature | -40°C to +60°C | |
| Humidity (without condensation) | 0% - 95% (10°C – 30°C) 0% - 75% (30°C – 40°C) 0% - 40% (40°C – 55°C) |
|
| Operating altitude | 2000 m | |
| Safety Specifications | ||
| General | IEC 61010-1: Pollution Degree 2 | |
| Measurement | IEC 61010-2-033: CAT IV 600V / CAT III 1000V | |
| Mechanical and General Specifications | ||
| Size | 203 x 100 x 50 mm (with holster) | |
| Weight | 624 g | |
| Warranty | 3 years | |
| Battery life alkaline | Meter use | 1000 hours |
| Insulation test use | Meter can perform at least 1000 insulation tests with fresh alkaline batteries at room temperature. These are standard tests of 1000 V into 1 MΩ with a duty cycle of 5 seconds on and 25 seconds off. | |
| IP rating | IP40 | |
Delivery to Gulf countries
For the rest of the world, please contact us
Customer Services
For fast and innovative support
Fast delivery
With best shipping companies
Secure payments
Shop with peace of mind
The Fluke 1577 Insulation Multimeter combine a digital insulation tester with a full-featured, true RMS digital multimeter in a single, compact, handheld unit, which provides maximum versatility for both troubleshooting and preventative maintenance.
| Specifications | ||
| Voltage DC | Maximum voltage | 1000 V |
| Accuracy | ±(0.2%+2) | |
| Maximum resolution | 0.001 V | |
| Voltage AC | Maximum voltage | 1000 V |
| Accuracy | ±(2%+3) | |
| Maximum resolution | 0.1 mV | |
| Current DC | Maximum amps | 400 mA |
| Amps accuracy | ±(1.0%+2) | |
| Maximum resolution | 0.01 mA | |
| Current AC | Maximum amps | 400 mA |
| Amps accuracy | ±(2.0%+2)* | |
| Maximum resolution | 0.01 mA | |
| Resistance | Maximum resistance | 50 MΩ |
| Accuracy | ±(1.2%+2) | |
| maximum resolution | 0.1Ω | |
| Insulation Test | ||
| Minimum test current @ 1kΩ/V | 1 mA | |
| Test voltages | 500, 1000 V | |
| Maximum resistance per test voltage | 50 V | |
| 100 V | ||
| 250 V | ||
| 500 V | ||
| 1000 V | 600 MΩ | |
| Maximum resolution per test voltage | 50 V | 0.01 MΩ |
| 100 V | 0.01 MΩ | |
| 250 V | 0.1 MΩ | |
| 500 V | 0.1 MΩ | |
| 1000 V | 0.1 MΩ | |
| Accuracy per test voltage | 50 V | ±(3% + 5) |
| 100 V | ±(3% + 5) | |
| 250 V | ±(1.5% + 5) | |
| 500 V | ±(2.0% + 5) | |
| 1000 V | ±(2.0% + 5) | |
| Environmental Specifications | ||
| Operating temperature | –20°C to +55°C | |
| Storage temperature | -40°C to +60°C | |
| Humidity (without condensation) | 0% - 95% (10°C – 30°C) 0% - 75% (30°C – 40°C) 0% - 40% (40°C – 55°C) |
|
| Operating altitude | 2000 m | |
| Safety Specifications | ||
| General | IEC 61010-1: Pollution Degree 2 | |
| Measurement | IEC 61010-2-033: CAT IV 600V / CAT III 1000V | |
| Mechanical and General Specifications | ||
| Size | 203 x 100 x 50 mm (with holster) | |
| Weight | 624 g | |
| Warranty | 3 years | |
| Battery life alkaline | Meter use | 1000 hours |
| Insulation test use | Meter can perform at least 1000 insulation tests with fresh alkaline batteries at room temperature. These are standard tests of 1000 V into 1 MΩ with a duty cycle of 5 seconds on and 25 seconds off. | |
| IP rating | IP40 | |