The SPR-213 is a high-range 1000A AC/DC True RMS clamp meter designed for accurate current and voltage measurements in industrial and electrical applications. It supports comprehensive measurement functions including AC/DC current, voltage, resistance, capacitance, frequency, duty cycle, temperature (Type K thermocouple), diode testing, continuity, and microamp (µA) measurement. The meter features a dual LCD display with 50,000 count resolution, non-contact voltage detection, data hold, backlight, auto-ranging, and auto power-off with safety protections suitable for demanding environments.
- True RMS AC/DC Current Measurement: Up to 1000A for accurate readings on non-linear loads
- AC/DC Voltage Measurement: Up to 600V with high accuracy
- Resistance Measurement: Up to 50MΩ for circuit testing
- Capacitance Measurement: Up to 5000µF for component testing
- Frequency and Duty Cycle Measurement: For signal analysis
- Microamp (µA) Measurement: For low current applications
- Type K Thermocouple Temperature Measurement: -100°C to 1000°C range
- Diode Test and Continuity Check: With audible indication
- Non-Contact AC Voltage Detection: For safe voltage presence verification
- Data Hold and MAX/MIN Recording: Capture and review measurements
- Backlit LCD Display: Dual display with 50,000 count resolution
- Auto Ranging and Manual Range Selection: For flexibility and precision
- Peak Hold Function: Captures transient signals
- Low Battery Indication: Alerts when battery replacement is needed
- Over-Range Indication ("OL"): Prevents measurement errors
- Safety Category CAT III 600V / CAT II 1000V: Safe for high voltage work
- 9V Battery Powered: Long battery life with auto power-off
- Automatic Power Off: With disable option for extended use
| Specification | Details |
|---|---|
| Current Measurement | DC: 50.00A / 1000.0A ±(2.5% + 5 digits) AC (True RMS): 50.00A / 1000.0A ±(2.5% + 5 digits) Frequency range: 50Hz–60Hz Valid from 5% to 100% of range |
| Voltage Measurement | DC: 500mV – 600V ±(0.1% + 4 digits) AC (True RMS): 500mV – 600V ±(1.0% + 30 digits) Bandwidth: 50Hz–1000Hz |
| Resistance | 500Ω – 50MΩ ±(1% to 3% + 5 to 10 digits) |
| Capacitance | 500nF – 5000µF ±(3.5% to 5% + 10 to 40 digits) |
| Frequency | 50Hz – 10MHz ±(0.3% + 2 digits) |
| Duty Cycle | 5.0% – 95.0% ±(1.0% + 2 digits) |
| Temperature | Type K Probe: -100°C to 1000°C (-148°F to 1832°F) Accuracy: ±(1.0% + 2.5°C or 4.5°F) |
| µA Measurement | DC: 500µA – 5000µA ±(1.0% + 6 digits) AC: 500µA – 5000µA ±(1.5% + 30 digits) |
| Display | Dual LCD: 50,000 count main + secondary display Backlit for low-light visibility |
| Clamp Jaw Opening | Approx. 1.9" (48mm) |
| Input Impedance | 10MΩ (for VDC and VAC) |
| Battery | 1 x 9V battery (NEDA 1604) |
| Battery Life | Auto power-off after ~30 minutes; disable option available |
| Dimensions & Weight | 9.1 x 3.0 x 1.6" (230 x 76 x 40mm), ~11.1 oz (315g) |
| Operating Temperature | 5°C to 40°C (41°F to 104°F) |
| Storage Temperature | -20°C to 60°C (-4°F to 140°F) |
| Safety Category | CAT II 1000V / CAT III 600V |
| Approvals | CE Marked |