{"product_id":"spartna-spr-218-ac-trms-leakage-clamp-meter","title":"SPARTNA SPR-218 AC TRMS Leakage Clamp Meter","description":"\u003cp dir=\"ltr\"\u003eThe AC TRMS Leakage Clamp Meter is a specialized digital clamp meter designed for accurate measurement of leakage currents in electrical systems. It features True RMS technology to ensure precision on both sinusoidal and non-sinusoidal waveforms. This device is ideal for electricians, engineers, and maintenance technicians who need to detect and measure small leakage currents that can indicate insulation degradation or electrical faults.\u003c\/p\u003e\n\u003ch5 dir=\"ltr\"\u003e\u003cstrong\u003eFeatures:\u003c\/strong\u003e\u003c\/h5\u003e\n\u003cul dir=\"ltr\"\u003e\n\u003cli\u003eTrue RMS Measurement: Ensures accuracy for distorted waveforms.\u003c\/li\u003e\n\u003cli\u003eLeakage Current Detection: High sensitivity for measuring low-level leakage currents.\u003c\/li\u003e\n\u003cli\u003eLarge Jaw Opening: Enables easy measurement around conductors without disconnection.\u003c\/li\u003e\n\u003cli\u003eAuto Ranging \u0026amp; Manual Range Selection: Offers flexibility for different measurement scenarios.\u003c\/li\u003e\n\u003cli\u003eLCD Display with Backlight: Improves visibility in low-light conditions.\u003c\/li\u003e\n\u003cli\u003eOverload Protection: Designed with double insulation and overvoltage protection.\u003c\/li\u003e\n\u003cli\u003eSafety Certified: Meets CAT II 600V \/ CAT III 300V safety standards.\u003c\/li\u003e\n\u003cli\u003eLow Battery Indicator: Alerts user when battery needs replacement.\u003c\/li\u003e\n\u003cli\u003eUser-Friendly Interface: Intuitive rotary switch and dedicated buttons for ease of use.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5 dir=\"ltr\"\u003e\u003cstrong\u003e Specifications:\u003c\/strong\u003e\u003c\/h5\u003e\n\u003cdiv dir=\"ltr\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth scope=\"col\"\u003eSpecification\u003c\/th\u003e\n\u003cth scope=\"col\"\u003eValue\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAC Current Ranges\u003c\/td\u003e\n\u003ctd\u003e6 mA, 60 mA, 600 mA, 6 A, 60 A, 100 A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003eDown to 1 µA (microampere)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy (50\/60Hz)\u003c\/td\u003e\n\u003ctd\u003e±(1.0% + 5 digits) to ±(1.5% + 8 digits), depending on range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy (\u0026gt;60Hz \u0026lt;1kHz)\u003c\/td\u003e\n\u003ctd\u003e±(3.0% + 5 digits) to ±(3.5% + 8 digits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrequency Response\u003c\/td\u003e\n\u003ctd\u003e50 to 1000Hz (sine); 50\/60Hz (all waveforms)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLPF Frequency\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;100Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Input\u003c\/td\u003e\n\u003ctd\u003e120A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eClamp Jaw Opening\u003c\/td\u003e\n\u003ctd\u003e1.26\" (32mm) approx.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003e6000 counts backlit LCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery\u003c\/td\u003e\n\u003ctd\u003e3 × 1.5V AAA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Life\u003c\/td\u003e\n\u003ctd\u003e~30 hours (backlight ON); ~100 hours (backlight OFF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAuto Power Off\u003c\/td\u003e\n\u003ctd\u003eAfter ~15 minutes of inactivity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Temperature\u003c\/td\u003e\n\u003ctd\u003e5°C to 40°C (41°F to 104°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Temperature\u003c\/td\u003e\n\u003ctd\u003e-20°C to 60°C (-4°F to 140°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHumidity\u003c\/td\u003e\n\u003ctd\u003eMax 80% RH up to 31°C, linear decrease to 50% at 40°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Category\u003c\/td\u003e\n\u003ctd\u003eOvervoltage Category III 300V, Pollution Degree 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSafety Standards\u003c\/td\u003e\n\u003ctd\u003eIEC61010-1: EN61010-2-030, EN61010-2-032, EN61010-2-033\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003chr\u003e\n\u003ch5 dir=\"ltr\"\u003e\u003cstrong\u003eDownloads:\u003c\/strong\u003e\u003c\/h5\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/0699\/6046\/6664\/files\/SPR-218_c0faf20a-fa55-4e05-9d6f-c55a15a39497.pdf?v=1789454715\"\u003e SPR-218\u003c\/a\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"Spartna","offers":[{"title":"Default Title","offer_id":49061239259368,"sku":"SPR-218","price":695.65,"currency_code":"SAR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0699\/6046\/6664\/files\/2J1A4265_800x_f80b047c-d5f7-4431-9d96-205c28076ceb.webp?v=1789389357","url":"https:\/\/mmt.com.sa\/products\/spartna-spr-218-ac-trms-leakage-clamp-meter","provider":"Measurement Methods Technology Company","version":"1.0","type":"link"}