The Radiodetection Lexxi T1660 is a high-resolution hand-held time domain reflectometer for locating faults on metallic cables with at least two metallic elements, including CATV, twisted pair telecom, Ethernet and LV power cables. It offers 1% accuracy, a 0.5 m dead zone, a 6 km maximum range and a 3.5" color display. It is supplied with 100Ω twisted pair alligator clip cables and a bag.
• Large 3.5" color backlit display
• 1% fault location accuracy
• 0.5 m dead zone
• Maximum range of 6 km (19,000 ft)
• 11 range settings from 7 m to 6000 m
• Selectable cable impedance: 25, 50, 75 and 100 Ω
• VoP adjustable from 1% to 99%
• Optional plug-in modules, including Cat IV mains Blocking Filter
| Ranges | 7, 15, 30, 60, 120, 250, 500, 1000, 2000, 3000, 6000 m |
| Accuracy | 1% of selected range |
| Resolution | Approx. 1% of range |
| Display | 328 x 256 pixel 3.5" color backlit LCD |
| Velocity of Propagation | 1% to 99%, adjustable |
| Output Pulse | 5 V peak to peak (into open circuit) |
| Output Impedance | 25, 50, 75 and 100 Ω |
| Pulse Width | 3 ns to 3 ms (automatic with range) |
| Batteries | Six AA alkaline or NiMH cells |
| Battery Life | 12 hours typical (alkaline) |
| Protection Rating | IP54 |
| Weight | 600 g (1.3 lb) |